Ramp testing pre-engineered wood floors

Original publication: 2007 | HSE Research Report | RR533

Source authors: Marianne Loo-Morrey (HSL)

About this research

Examines how engineered timber and laminate flooring performs in wet slip tests, comparing a human-based ramp with portable floor-assessment methods.

How the research was conducted

HSL assessed a range of pre-engineered wood flooring products using its human-subject ramp method, wet pendulum friction measurements and Rz microroughness assessment.

Main findings and significance

The study found appreciable variation between floor products and differences in classification between the portable methods. Its comparisons help explain the limits of predicting performance from material labels or one surface descriptor.

Interpretation and limitations

The findings describe the specific finishes and samples assessed, not all wooden floors or current versions of branded products.

Original source and further reading

Download the HSE report (PDF, 35 pages)

Official HSE research-report catalogue (501–600)

Original HSE publication, preserved without alteration. Crown copyright; see the original report for its copyright and reuse terms. Neospire’s summary is separate from the original research.